Wafr supplies integrated power conversion and voltage boosting systems that combine a Power Conversion System (PCS), step-up transformer and associated distribution equipment within a compact cabinet or skid-mounted configuration. The integrated design is intended to simplify transportation, installation, operation and maintenance while reducing on-site system complexity.

Key Specifications

SpecificationConfiguration
Maximum DC Bus Voltage850 V / 1,500 V
Maximum DC Side Current1,147–2,500 A per string (×2 or ×4 strings depending on model)
DC Voltage Operating Range580–850 V (850 V bus); 1,000–1,500 V (1,500 V bus)
Number of DC Input Circuits1–4 (model dependent)
Rated Power1,000 / 2,500 / 3,150 / 3,450 / 5,000 / 6,250 kW
Branch Power × Quantity500 kW×2, 630 kW×4, 2,500 kW×1 + 1,250 kW×2, 3,150 kW×1, 1,725 kW×2, 2,500 kW×2 + 1,250 kW×4, 1,563 kW×4
Maximum Output Power1,100 / 2,750 / 3,465 / 3,795 / 5,500 / 6,250 kW
Isolation MethodTransformer isolation
Reactive Power Range0 to ±1,050–6,250 kvar (model dependent)
Rated Grid Voltage6 / 10 / 35 kV
Rated Grid Frequency50 / 60 Hz
Total Current Harmonic Distortion Rate< 3%
Power Factor-1 to 1
Transformer Rated Capacity1,000 / 2,500 / 3,150 / 3,450 / 5,000 / 6,250 kVA
Transformer TypeDry-type or oil-immersed
Transformer LV/MV Voltage0.4 or 0.69 kV / 6–35 kV
Transformer No-Load Loss, Load Loss, No-Load Current, ImpedanceCompliant with national standards
Permitted Ambient Temperature-30°C to +60°C (derating above 40–50°C depending on model)
Permitted Relative Humidity0–100%
Permitted Altitude<5,000 m (derating above 2,000–4,000 m depending on model)
Protection RatingIP54
BMS Communication InterfaceRS485
EMS Communication InterfaceEthernet
Communication ProtocolModbus RTU / Modbus TCP / IEC104 / IEC61850
Compliance with StandardsGB/T34120, GB/T34133, GB/T36547
Grid SupportHVRT/LVRT, frequency regulation, voltage regulation, grid-forming function, etc.
Overall DimensionsDepending on specific configuration
WeightDepending on specific configuration

Available Configurations

Integrated PCS and Transformer

Combines a Power Conversion System and step-up transformer within a single cabinet or skid-mounted configuration.

Compact Cabinet Design

Compact integrated or skid-mounted enclosure simplifies transportation, installation and on-site commissioning.

Integrated Protection Systems

Built-in fire protection, access control and cooling systems support safe, unattended operation.

Product Composition

The main components include a containerized system integrating the energy storage converter (PCS), mounted on an outdoor skid-mounted base when in skid-mounted configuration, voltage boosting transformer, high-voltage ring main unit, low-voltage distribution cabinet, and other equipment. This design features high integration that reduces on-site construction complexity while offering simplified transportation, installation, operation, and maintenance. Such integrated design delivers numerous significant advantages.

Product Features

  • Energy Storage Converter (PCS): Installed on the skid-mounted integrated base, this AC/DC conversion device serves as the primary execution unit for controlling battery charging and discharging processes. Composed of a DC/AC bidirectional converter, control unit, and filter circuit. The control unit receives operational commands to manage the converter's charging/discharging operations on the DC battery side while regulating active and reactive power on the AC side.
  • Step-Up Transformer Cabin: The integrated cabin with a built-in transformer is compatible with voltage levels up to 35kV and below, designed to achieve electrical energy step-up functionality. Through the step-up transformer, the energy storage device (PCS) can elevate low-voltage electrical energy to the required high-voltage level, meeting the demand for high-voltage power in long-distance transmission or specific load systems. Simultaneously supports both local and remote monitoring.
  • Integrated Safety Systems: The cabin incorporates an emergency lighting system, fire protection system, access control system, and cooling system. Fireproof partitions within the enclosure effectively ensure the normal operation and safety of internal equipment in the integrated step-up cabin.
  • Compact Footprint: The integrated design significantly reduces the footprint required for equipment installation. Compared to traditional decentralized inverters and step-up equipment, it consolidates complex circuits and components within a single cabin, minimizing interconnection wiring and line losses while creating a more compact and aesthetically cohesive system.
  • Peak Shaving and Load Leveling: The system enables energy storage and release in response to grid load fluctuations, achieving power system peak shaving. During grid load peaks, the energy storage device can discharge stored electricity to alleviate load pressure; during grid load troughs, the device absorbs surplus electricity for storage, preventing system overload and maintaining grid stability.
  • Grid Stability Enhancement: Enables improvement in grid frequency and voltage stability. When significant fluctuations occur in grid frequency or voltage, the energy storage device can promptly discharge or store energy to maintain grid operation within reasonable parameters.
  • Emergency Backup Power Supply: When the power system encounters sudden failures or outages, the energy storage device can swiftly switch to emergency backup power mode, providing continuous and stable power supply to critical loads while ensuring operation of essential facilities.

Key Features

  • Integrated PCS and voltage step-up functionality
  • Dry-type or oil-immersed transformer configurations
  • Compact integrated cabinet or skid-mounted design
  • Active and reactive power regulation
  • Local and remote monitoring capability
  • Integrated fire protection, access control and cooling systems
  • Peak shaving and load leveling capability
  • Grid frequency and voltage support
Let's connect